After you connect an auxiliary input to the VG or powered AG, such as the AG26/46P/52, you can configure the type and pin assignment from the asset overview.
Use the following workflow to configure the auxiliary inputs for your asset:
-
On the Dashboard Overview, select the asset for which you connected an auxiliary input.
-
From the more actions menu ( ... ), select Settings.
-
In the Aux Input list, click + Add Aux Input. To configure an auxiliary engine, see Configure an Input as Auxiliary Engine.
-
Select the Aux Input Type or Other if the type doesn't fit into the predefined categories.
-
Select the Input Number that corresponds to the pin assignment.
-
Save the asset settings.
After you save the settings, you can view the status of the input in the
Diagnostic
section of vehicle details. To view a graph of diagnostic information for the selected time period above the vehicle map, select the input type from the Graph data drop-down.
To Configure an Auxiliary Input as an auxiliary engine using CBL-AG-APWR cable (AG26/46P) or CBL-AG-BPWR cable (AG52), use the following workflow:
-
For Aux Input Type, select Auxiliary Engine for Input Number 1.
-
Within Engine hours, select Edit and provide your starting engine hour value.
Value must be greater than 0.
-
Click Save to confirm the changes and update the engine hours.