[en] Refer to the installation instructions of your FORCE America controller model:
-
[en] Verify whether data logging is installed on the controller.
[en] If the controller has Data Logging enabled (also known as Option E) it will indicate it on the bootup screen.
[en] If the controller doesn’t have Data logging enabled, contact FORCE America for the Upgrade Key. The data logging key is black.
-
[en] Connect the 5100 controller.
-
[en] Using the ACC-RS232 cable provided with the Samsara Vehicle Gateway (VG), plug the USB end into the VG.
-
[en] Plug the serial port into the FORCE America 5100 controller. The port is located in the cable bundle connected to the back of the 5100 Controller.
-
-
[en] Enable and Data Logging on the 5100 controller.
[en] Follow the instructions for Calibration of the Event Logging Option in the FORCE America 5100 Data Logging Setup Guide.
[en] For the Calibration Worksheet referenced in the setup, see the following table:
[en] Setting
[en] Value
[en] Baud Rate
9600
[en] Protocol
[en] FORCE
[en] Storage Location
[en] On Board & External
[en] Low Storage Alarm
[en] 75%
[en] Data Format
[en] LONG
[en] Data Field (1-37)
[en] Yes
[en] Event Trigger Selection (1-37)
[en] Yes to all (some triggers may be missing)
[en] Time Interval
00:05
[en] Include Standby Time
[en] Yes
[en] Distance Interval
5
[en] Include Standby Distance
[en] YES
[en] Granular Interval
5
[en] PreWet Interval
5
[en] Direct Interval
5
[en] Route Option Enable
[en] NO
[en] If you are using an external temperature sensor, you will need an extra cable.
-
[en] Plug the Samsara Spreader Cable into the FORCE America 5100ex.
[en] The serial connection port is located on the back of the display unit.
-
[en] Configure the Active Vehicle Locating Interface (AVL) on the 5100ex controller.
Note
[en] You may need a password or a configuration USB for the header unit to access Config settings.
[en] On the Header unit of the 5100ex, navigate to Calibration > Config > Event Logging. Then enable AVL.
-
[en] Verify that Samsara is receiving the spreader data.
-
[en] Turn on the vehicle and turn the spreader controller dial to any amount.
-
[en] From the Overview page on your Samsara dashboard, search for and then select the vehicle in the list that you want to test.
-
[en] From the Graph Data drop down, select Spreader and ensure the date selector is set to display data for Today.
[en] The graph should display material data reported by your spreader controller.
-
-
[en] Notify your Samsara representative which gateways are connected to the spreader.
[en] The FORCE America 6100 (versions 1-4) require an Event Logging Authentication (ELA) Module and a data logging key. The module configures the system to use AVL Event Logging.
-
[en] Plug Samsara Spreader Cable (RS232) into FORCE America 6100.
-
[en] Plug the ELA Module into the port.
-
[en] Configure the spreader controller.
-
[en] To open the Configuration menu of the 6100 Unit, press the right or left on the smaller gray knob.
-
[en] Enter the code to unlock access if needed.
-
[en] Navigate to Configuration > Enabled Options > Event Logging (Serial).
-
[en] Change this option to AVL.
-
-
[en] Verify that Samsara is receiving the spreader data.
-
[en] Turn on the vehicle and turn the spreader controller dial to any amount.
-
[en] From the Overview page on your Samsara dashboard, search for and then select the vehicle in the list that you want to test.
-
[en] From the Graph Data drop down, select Spreader and ensure the date selector is set to display data for Today.
[en] The graph should display material data reported by your spreader controller.
-
-
[en] Notify your Samsara representative which gateways are connected to the spreader.
[en] The FORCE America 6100 (version 2-4) requires an ELA module and a data logging key. The 6100 Gen 5 does not require a data logging key.
-
[en] Plug Samsara Spreader Cable (RS232) into FORCE America 6100.
[en] Using the provided Orange adapter labeled
Null Modem
, plug the Samsara serial cable into the AVL port on the FORCE America 6100 hub. This hub is typically mounted between the seats. -
[en] Configure the spreader controller.
-
[en] To open the Configuration menu of the 6100 Unit, press the right or left on the smaller gray knob.
-
[en] Enter the code to unlock access, if needed.
-
[en] Navigate to Configuration > Enabled Options > Event Logging (Serial).
-
[en] Change this option to AVL.
-
-
[en] Verify that Samsara is receiving the spreader data.
-
[en] Turn on the vehicle and turn the spreader controller dial to any amount.
-
[en] From the Overview page on your Samsara dashboard, search for and then select the vehicle in the list that you want to test.
-
[en] From the Graph Data drop down, select Spreader and ensure the date selector is set to display data for Today.
[en] The graph should display material data reported by your spreader controller.
-
-
[en] Notify your Samsara representative which gateways are connected to the spreader.
Commentaires